• Double Ended Sliding Tube Clamp Adapter with Receiver

Double Ended Sliding Tube Clamp Adapter with Receiver

Precision double-ended sliding tube clamp adapter with receiver for lower-limb prosthetic systems, supporting tube fixation, sliding adjustment and mo

Discuss Your Project

Drawings welcome (STEP / IGS / PRT / PDF).
Reply within 24 hours.


Precision-machined double ended sliding tube clamp adapter with receiver for lower-limb prosthetic systems, supporting tube fixation, sliding adjustment and receiver-based modular assembly.

Sunrise Industrial manufactures double ended sliding tube clamp adapters with receiver for prosthetic component applications requiring secure tube fixation, receiver connection, sliding adjustment and stable structural support. This naming helps distinguish the product from the standard double ended sliding adapter with receiver.

This component may also be described as a sliding tube clamp adapter with receiver, double-ended sliding tube clamp adapter, prosthetic sliding tube clamp adapter or sliding receiver tube clamp adapter. It can be manufactured in titanium, stainless steel or other suitable materials according to drawings, samples and project-specific requirements.

Double Ended Sliding Tube Clamp Adapter with Receiver Sliding Tube Clamp Adapter with Receiver Double-Ended Sliding Tube Clamp Adapter Tube Clamp Adapter with Receiver Prosthetic Sliding Tube Clamp Adapter Custom Prosthetic Adapter
Double ended sliding tube clamp adapter with receiver for lower-limb prosthetic modular connection and sliding adjustment

Double ended sliding tube clamp adapter with receiver for modular lower-limb prosthetic assembly.

Product Overview

Sliding Tube Clamp Structure

The tube clamp area supports secure tube fixation, while the sliding structure helps provide practical positioning and alignment adjustment during prosthetic assembly.

Receiver-Based Connection

The receiver interface supports integration with compatible prosthetic components, helping provide stable modular assembly and reliable fitting performance.

Key Features

  • Double ended sliding tube clamp adapter structure
  • Tube clamp section for secure tube fixation
  • Receiver interface for modular component connection
  • Sliding adjustment for practical alignment and assembly positioning
  • Suitable for lower-limb prosthetic component systems
  • Available in titanium, stainless steel and custom material options
  • Custom sliding range, clamp details and receiver geometry available
  • Manufactured according to drawings, samples or technical specifications

Custom Manufacturing and Specifications

We manufacture double ended sliding tube clamp adapters with receiver according to customer drawings and project requirements. Customization may include sliding range, tube clamp dimensions, receiver interface, screw holes, thread details, material selection, surface finish, marking and packaging.

Product Type Double Ended Sliding Tube Clamp Adapter with Receiver / Sliding Tube Clamp Adapter with Receiver / Double-Ended Sliding Tube Clamp Adapter
Application Lower-limb prosthetic modular connection, tube fixation, sliding adjustment, alignment and structural support applications
Main Function Tube clamp fixation with receiver connection and sliding adjustment
Connection Type Double ended sliding structure with tube clamp section and receiver interface according to drawing requirements
Available Materials Titanium, stainless steel and other suitable materials according to project requirements
Manufacturing Method Precision CNC machining based on customer drawings, samples and technical requirements
Customization Sliding range, tube clamp dimensions, receiver geometry, screw holes, thread details, material, finish, marking and packaging
Production Basis 3D files, 2D drawings, samples, dimensional requirements and project-specific specifications

Applications and Quality Control

Double ended sliding tube clamp adapters with receiver are used in lower-limb prosthetic systems where tube fixation, receiver connection, sliding adjustment and stable structural support are required.

  • Lower-limb prosthetic component systems
  • Sliding tube clamp adapter applications
  • Tube clamp and receiver connection projects
  • Prosthetic alignment adjustment components
  • OEM prosthetic component supply
  • Custom machined prosthetic hardware

Quality control covers raw material selection, dimensional inspection, sliding fit, tube clamp geometry, receiver geometry, screw hole position, thread quality, surface finish and final appearance review.

For sliding tube clamp adapters, secure clamping, smooth adjustment, stable locking and repeatable assembly fit are important for practical prosthetic use and long-term supply.

Prosthetic Components Manufacturing Range

prosthetic adapter components display including sliding tube clamp adapters with receiver double ended adapters socket adapters and modular lower-limb prosthetic parts

In addition to double ended sliding tube clamp adapters with receiver, Sunrise Industrial manufactures a range of prosthetic adapter components for socket connection, tube connection, receiver connection, pyramid connection, foot connection and modular assembly applications.

This representative display image is used to show our overall prosthetic component manufacturing range and machining experience. The final product structure, dimensions, material and finish should always follow the customer drawing and project requirements.

This image represents our prosthetic adapter manufacturing capability and product range. It is not used as a single-model product photo.

Why Choose Sunrise Industrial

Sunrise Industrial has practical manufacturing experience in prosthetic components and precision CNC-machined metal parts. We support drawing-based production for customers requiring double ended sliding tube clamp adapters with receiver and related lower-limb prosthetic components.

For customers looking for dependable manufacturing support, we provide flexible custom production, responsive communication, drawing review support and consistent product quality for prosthetic component requirements.

Frequently Asked Questions

What is a double ended sliding tube clamp adapter with receiver used for?

It is used in lower-limb prosthetic systems where tube fixation, receiver connection, sliding adjustment and stable structural support are required.

How is it different from a double ended sliding adapter with receiver?

This version includes a tube clamp structure, while a standard double ended sliding adapter with receiver may not include the same tube clamp fixation design.

What does the sliding structure do?

The sliding structure supports practical positioning and alignment adjustment during modular prosthetic assembly.

What does the tube clamp structure do?

The tube clamp section is designed for secure tube fixation according to the required tube size and drawing details.

What materials are available?

We can manufacture this product in titanium, stainless steel and other suitable materials according to project requirements.

Can the sliding range and clamp details be customized?

Yes. Sliding range, tube clamp dimensions, receiver details, screw holes and overall dimensions can be customized according to drawings.

What drawing formats can you review?

3D files and 2D drawings are welcome, including STEP/STP, IGS, X_T, SLDPRT, PRT and PDF. Other common drawing formats may also be reviewed if available.

Need a Quotation for Double Ended Sliding Tube Clamp Adapters with Receiver?

Send us your drawing, sliding range, tube clamp details, receiver details, material, quantity or application information for quotation. We support custom sliding tube clamp adapter manufacturing for prosthetic component projects.

3D files and 2D drawings welcome: STEP/STP, IGS, X_T, SLDPRT, PRT, PDF and more.

Related Products

Support for Sliding Tube Clamp Adapters with Receiver

Sunrise Industrial provides drawing-based CNC machining support for double ended sliding tube clamp adapters with receiver, focusing on tube clamp fit, sliding adjustment, receiver geometry and stable lower-limb prosthetic assembly.

01

Tube Clamp Fit

Tube clamp dimensions, split details, screw holes and locking areas can be controlled according to drawing requirements.

02

Sliding Adjustment

Sliding range, adjustment position and locking details can be reviewed for practical alignment and assembly needs.

03

Receiver Interface

Receiver geometry, thread details and assembly fit are inspected for reliable modular prosthetic connection.

04

Custom Production

Material, finish, marking, packaging and small-quantity production can be supported based on drawings or samples.

For quotation, please send your 2D drawing, 3D file, tube size, sliding range, receiver details, material requirement and quantity. We will review feasibility and provide practical manufacturing feedback.

Request a Quote

Share your requirements and drawing. We will review and reply quickly.

Add key specs for faster quotation.
No file chosen
PDF, STEP, DWG, JPG, PNG
Your files will be kept confidential.